Maxron R507 is an HFC azeotropic blend of R125 and R143a (50/50 percent), also called R507A, used in low and medium temperature commercial refrigeration.
It is supplied in Maxron cylinders. Tell us the cylinder size and quantity. Then we will confirm stock and send a quote.
What is a Maxron R507?
R507 is an HFC azeotropic blend of R125 and R143a (50/50 percent), also called R507A. It is used in low and medium temperature commercial refrigeration. As an azeotrope it behaves like a single gas, with almost no glide.
Its global warming potential (GWP) is 3985 on the IPCC AR4 scale, and its ASHRAE safety class is A1 (non-flammable, lower toxicity). Systems on R507 normally use POE oil. Therefore, always use the refrigerant and oil shown on the equipment nameplate.
Further reading
- Refrigerants (Wikipedia)
- List of refrigerants and properties (Wikipedia)
- Montreal Protocol (Wikipedia)
Key terms explained
- GWP
- Global warming potential: how strongly a gas warms the climate compared with carbon dioxide.
- ASHRAE safety class
- A rating of toxicity (A or B) and flammability (1, 2L, 2 or 3).
- Blend and glide
- A blend mixes several gases. Glide is the temperature change as it boils.
- Liquid charging
- Charging blends from the liquid side so the mix stays correct.
- Recovery
- Removing refrigerant into a cylinder instead of venting it.
Features and benefits
- Matched to the equipment refrigerant.
- Sealed cylinders.
- Several brands and sizes.
- Standard published properties.
- Supports service and new installations.
Technical specifications
| Product | Maxron R507 |
|---|---|
| Refrigerant | R507 |
| Type | An HFC azeotropic blend of R125 and R143a (50/50 percent), also called R507A |
| GWP (IPCC AR4) | 3985 |
| ASHRAE safety class | A1 (non-flammable, lower toxicity) |
| Boiling point at 1 atm | about -47 degrees Celsius |
| Typical oil | POE oil |
| Brand | Maxron |
| Cylinder size | Confirm with quote |
| Supplier | Sparks Plumbing Experts Ltd, Nairobi |
| Supplier | Sparks Plumbing Experts Ltd, Nairobi |
Property values are standard published figures for R507. Cylinder size, brand and stock vary, so confirm them with your quote.
Applications of a Maxron R507
- Freezer rooms. Low temperature storage.
- Cold rooms. Medium temperature storage.
- Supermarket refrigeration. Display and storage.
- Ice plants. Ice production.
- Blast freezers. Fast freezing.
- Transport refrigeration. Refrigerated vehicles.
- Food processing. Process cooling.
- Service. Recharging R507 systems.
How to choose and install
- Use only the refrigerant on the nameplate.
- Never mix gases or top up with a different refrigerant.
- Charge blends as liquid, by weight.
- Use tools rated for the pressure and flammability class.
- Recover old gas and follow NEMA and local rules for controlled substances.
Why choose Sparks Plumbing Experts
- Gases, oils and parts togetherRefrigerants, compressor oils, copper pipe, driers and tools come from one counter, so a repair needs one trip.
- Brands technicians knowOur range includes names such as Danfoss, Maxron, Suniso and Emkarate.
- Compatibility checksWe point out refrigerant, oil and voltage compatibility before you buy, which helps avoid costly mistakes.
- Tools for the whole jobGauges, flaring kits, brazing torches and gas are stocked alongside the parts they install.
- Visit or collect in NairobiOur store is at KCB Building, Enterprise Road, in the Industrial Area, so you can see parts before you buy or collect your order.
- Quotes your wayAsk for prices by phone, WhatsApp, email or the online quote form, whichever suits you on site.
- Over 1,600 products in one placeOur catalogue covers 55 categories, so one supplier can handle most of your parts list.
- Help choosing the right partSend a nameplate photo, a drawing or the old part, and we help you match size and specification.
- Single items or project quantitiesWe price a single replacement part just as readily as a full site order.
- Supply across East AfricaWe serve customers across Kenya, and we also supply buyers in Uganda and Tanzania.
Related products and accessories
Browse more: Refrigeration Gases · Compressors · AC and refrigeration tools · Refrigeration Oils.
Ordering from Sparks Plumbing Experts
We supply customers across Kenya, and we also serve buyers in Uganda and Tanzania. You can collect from our store at KCB Building, Enterprise Road, Nairobi, or ask us about delivery to your site. Send your quantities and specifications, and we will reply with prices and availability.
Request a Quote WhatsApp 0726 086 895
Frequently asked questions
What is R507 used for?
It is used in low and medium temperature commercial refrigeration.
What is the GWP of R507?
3985 on the IPCC AR4 100-year scale.
Is R507 flammable?
Its ASHRAE safety class is A1 (non-flammable, lower toxicity).
Is Maxron R507 the same as other R507 brands?
The refrigerant is the same chemical type. The brand is the maker or packer of the cylinder.
What details do you need to quote refrigerant gases?
Tell us the refrigerant type, cylinder size and quantity. A photo of the old part, a nameplate or a drawing also helps. Then call or WhatsApp 0726 086 895, or use the quote form on this page.
Do you deliver refrigerant gases outside Nairobi?
Yes. We supply customers across Kenya, and we also serve buyers in Uganda and Tanzania. Delivery or courier arrangements are agreed when you confirm the order.
How much does a refrigerant cylinder cost in Kenya?
The price depends on the gas, brand and cylinder size. Therefore, send your list with a quote request and we will reply with current figures.
Can I mix two refrigerants?
No. Mixing makes the system unsafe and hard to service.
Why charge blends as liquid?
The gases in a blend boil at different temperatures, so vapour charging changes the mix.
Who should handle refrigerants?
Trained technicians with suitable tools, following NEMA and local rules.
How do I store refrigerant cylinders?
Upright, cool, shaded and away from heat and flames.
Should old refrigerant be vented?
No. Recover it into a recovery cylinder.
People also search for
R410A vs R32
R32 has lower GWP and is mildly flammable. R410A is non-flammable with higher GWP.
R404A vs R507
Both suit low temperature work. R507 is azeotropic, R404A has a small glide.
R134a vs R600a in fridges
R600a is used in many new fridges. They are not interchangeable without changing the compressor.
R22 replacement options
New systems use R410A or R32. Some R22 systems can use R407C after checks.
how to charge refrigerant
Evacuate, then charge by weight to the nameplate amount, liquid for blends.
refrigerant leak detection
Use an electronic detector or bubble solution, then repair and pressure test.
Refrigerant gas price in Kenya
Prices change with size, model and quantity. Request a quote from Sparks Plumbing Experts for current figures.
refrigerant cylinder sizes
Cylinders come in several sizes. Ask us what is in stock.








Reviews