Maxron R410A Refrigerant Gas

Maxron R410A refrigerant for modern split air conditioners, VRF systems and heat pumps. Charge as a liquid with R410A-rated gauges and hoses.

R410A refrigerant is the standard gas in many modern split air conditioners, VRF systems and heat pumps. Sparks Plumbing Experts supplies the Maxron R410A brand in Kenya, Uganda and Tanzania to AC technicians and refrigeration contractors.

R410A works at higher pressures than older R22 systems. Therefore, technicians must use R410A-rated gauges, hoses and recovery equipment when charging it.

What is R410A refrigerant?

A refrigerant is the working fluid that carries heat inside an air conditioner. It absorbs heat as it evaporates in the indoor coil, then releases that heat as it condenses in the outdoor coil.

R410A is a hydrofluorocarbon (HFC) blend made of equal parts by weight of R32 and R125. It contains no chlorine, so it does not damage the ozone layer, unlike R22. However, it has a high global warming potential, so the Kigali Amendment to the Montreal Protocol is gradually phasing down HFCs like it. Many new systems now use R32 instead.

Further reading

Key terms explained

HFC
Hydrofluorocarbon, a refrigerant family that contains no chlorine.
ODP
Ozone depletion potential; R410A's is zero.
GWP
Global warming potential compared with carbon dioxide.
Blend
A mixture of refrigerants; R410A must be charged as a liquid to keep the mix correct.
POE oil
Polyolester oil, the lubricant used with R410A compressors.

Features and benefits

  • Zero ozone depletion potential
  • Good cooling capacity in compact systems
  • Standard refrigerant for many split ACs and heat pumps
  • Near-azeotropic blend with very little temperature glide
  • Non-flammable under normal conditions (ASHRAE safety class A1)
  • Supplied in sealed cylinders for professional use

Technical specifications

Product Maxron R410A refrigerant
Refrigerant type HFC blend, R32/R125 (50/50 by weight)
Ozone depletion potential 0
Safety class A1 (lower toxicity, no flame propagation)
Compatible oil POE (polyolester)
Charging As liquid, from an upright or inverted cylinder as marked
Packaging Refillable or disposable cylinders (confirm size with quote)
Supplier Sparks Plumbing Experts Ltd, Nairobi

Cylinder size and stock vary. Ask us for the current cylinder weight and the safety data sheet before purchase.

Applications of R410A refrigerant

  1. Split air conditioners. Charging and topping up R410A wall-mounted units.
  2. Ducted systems. Servicing ducted splits in offices and homes.
  3. VRF/VRV systems. Charging multi-indoor-unit systems after installation.
  4. Heat pumps. Servicing air-source heat pumps for water heating.
  5. Packaged rooftop units. Recharging packaged units on commercial roofs.
  6. Cassette units. Servicing ceiling cassette air conditioners.
  7. New installations. Adding trim charge for long pipe runs on new systems.
  8. Leak repairs. Recharging systems after a leak has been found and fixed.
  9. Hotels. Maintaining room and corridor AC systems.
  10. Hospitals. Keeping critical comfort cooling running.
  11. Data rooms. Servicing R410A comfort and close-control units.
  12. Supermarkets. Servicing R410A air-conditioning plant.
  13. Schools. Maintaining classroom and office units.
  14. Service contracts. Planned maintenance across many sites.
  15. Training. Teaching safe high-pressure refrigerant handling.

How to choose and install

  • Only use R410A in systems designed for it; never mix it with R22 or other gases.
  • Charge as a liquid, slowly, to keep the blend correct.
  • Use gauges, hoses and recovery units rated for R410A pressures.
  • Find and repair leaks before recharging a system.
  • Weigh the charge with scales rather than guessing from pressures.
  • Recover old refrigerant instead of venting it to the air.

Why choose Sparks Plumbing Experts

  1. Gases, oils and parts togetherRefrigerants, compressor oils, copper pipe, driers and tools come from one counter, so a repair needs one trip.
  2. Brands technicians knowOur range includes names such as Danfoss, Maxron, Suniso and Emkarate.
  3. Compatibility checksWe point out refrigerant, oil and voltage compatibility before you buy, which helps avoid costly mistakes.
  4. Tools for the whole jobGauges, flaring kits, brazing torches and gas are stocked alongside the parts they install.
  5. Visit or collect in NairobiOur store is at KCB Building, Enterprise Road, in the Industrial Area, so you can see parts before you buy or collect your order.
  6. Quotes your wayAsk for prices by phone, WhatsApp, email or the online quote form, whichever suits you on site.
  7. Over 1,600 products in one placeOur catalogue covers 55 categories, so one supplier can handle most of your parts list.
  8. Help choosing the right partSend a nameplate photo, a drawing or the old part, and we help you match size and specification.
  9. Single items or project quantitiesWe price a single replacement part just as readily as a full site order.
  10. Supply across East AfricaWe serve customers across Kenya, and we also supply buyers in Uganda and Tanzania.

Related products and accessories

Browse more: Refrigeration Gases · Refrigeration Oils · AC and refrigeration tools · Copper pipes · Compressors.

Ordering from Sparks Plumbing Experts

We supply customers across Kenya, and we also serve buyers in Uganda and Tanzania. You can collect from our store at KCB Building, Enterprise Road, Nairobi, or ask us about delivery to your site. Send your quantities and specifications, and we will reply with prices and availability.

Request a Quote WhatsApp 0726 086 895

Frequently asked questions

What is R410A used for?

It is the refrigerant in many modern split ACs, VRF systems, packaged units and heat pumps.

Can I put R410A in an R22 system?

No. R410A runs at much higher pressure and needs a different oil, so it is not a drop-in replacement for R22.

Is R410A harmful to the ozone layer?

No. It contains no chlorine, so its ozone depletion potential is zero. It does, however, have a high global warming potential.

Why must R410A be charged as liquid?

It is a blend of two gases. Charging as vapour can change the mix, so technicians charge it as liquid.

What colour is an R410A cylinder?

R410A cylinders are commonly rose or pink, but always read the label rather than relying on colour.

Is R410A flammable?

Under normal conditions it is classified A1, meaning lower toxicity and no flame propagation. Still, keep cylinders away from heat.

What oil does R410A use?

R410A systems use POE (polyolester) oil, which absorbs moisture easily, so keep systems sealed.

Is R410A being phased out?

HFCs such as R410A are being phased down under the Kigali Amendment, and many new units now use R32. R410A is still needed to service existing systems.

What safety equipment do I need?

Wear gloves and eye protection, work in ventilated areas, and use R410A-rated gauges and hoses.

How should I store the cylinder?

Store it upright, in a cool, dry, ventilated place, away from direct sun and heat sources.

Do you deliver outside Nairobi?

We supply customers across Kenya, and we also serve buyers in Uganda and Tanzania. Gas transport details come with your quote.

How do I get a price?

Request a quote or message us on WhatsApp with the number of cylinders. We reply with current prices and stock.

People also search for

R410A gas price in Kenya

Prices depend on brand and cylinder size. Send the quantity you need for a quote.

R410A vs R32

R32 is a single refrigerant with a much lower global warming potential (675) than R410A (2088), and it is mildly flammable (class A2L). R410A is class A1.

R410A vs R22

R22 contains chlorine and damages the ozone layer, so it has been phased out in new equipment. R410A runs at higher pressure and uses POE oil, so the two are not interchangeable.

R410A pressure chart

Saturation pressure rises with temperature, so technicians read pressures against a pressure-temperature chart or a digital gauge set for R410A.

R410A boiling point

At atmospheric pressure, R410A boils at about -48.5 °C, which is why liquid on skin causes frostbite.

Can R410A be mixed with R32?

No. Never mix refrigerants. Recover the old charge before changing to a different gas, and only where the system is designed for it.

How to charge R410A

Charge as liquid, weigh the amount with scales using the nameplate charge plus any pipe-length top-up, then confirm with superheat or subcooling readings.

R410A leak detection

Technicians use electronic leak detectors, soap solution and a nitrogen pressure test to find leaks before recharging.

Is R410A being banned?

HFCs such as R410A are being phased down under the Kigali Amendment. Check current national rules with Kenya's National Environment Management Authority (NEMA).

R410A global warming potential

R410A has a global warming potential of 2088, meaning 1 kg has the climate effect of about 2,088 kg of carbon dioxide over 100 years.

Reviews

There are no reviews yet.

Be the first to review “Maxron R410A Refrigerant Gas”

Your email address will not be published. Required fields are marked *

Request a Quote

List the items, sizes and quantities you need. We reply with prices and availability.